Date |
Jul Date |
Time |
Battery (V) |
T (ºC) |
Power (W) |
Disk (GB) |
Usage (%) |
M1 (V) |
M2 (V) |
M3 (V) |
M1f (V) |
M2f (V) |
M3f (V) |
Task |
Comments |
Techs |
2010-01-27 | 2010/027 | 12:30:00 | 12.7 | 14.1 | 0.0 | 12.8 | 3.26 | -0.42 | -0.31 | -0.88 | -0.06 | 0.10 | -0.01 | Change of disk (CF16Gb-CFHDD). Masses' tuning | Unable to read CF data | GM, JQ |
2010-03-10 | 2010/069 | 13:56:00 | 13.9 | 18.2 | 0.0 | 19.53 | 11.6 | 0.12 | 0.02 | -0.02 | 0.12 | 0.02 | -0.02 | Change of disk (HDD-HDD). | HDD in 763C612BW, HDD out 680072W D-19. Stores saved as 1046 instead of 1106 due to lack of formatting before reuse. | JP, JQ |
2010-05-12 | 2010/132 | 10:29:00 | 13.8 | 21.3 | 0.0 | 19.53 | 15.6 | 0.27 | 0.19 | 0.12 | 0.03 | -0.02 | 0.01 | Change disk. Masses'tuning. | - | JP, JQ |
2010-06-22 | 2010/173 | 11:22:00 | 14.0 | 41.7 | 0.0 | 19.53 | 9 | 0.65 | -0.06 | 0.00 | -0.03 | 0.04 | -0.01 | Change disk. Masses' tuning. Sealing improved | - | DN, JP |
2010-09-30 | 2010/273 | 11:12:00 | 14.1 | 32.3 | 0.0 | - | 22.8 | 0.75 | -0.85 | -0.86 | 0.04 | 0.06 | -0.09 | Masses'tuning. | The drive is left on the station as no other devices have been recognized by the Datalogger. To be replaced on a further check. | JP, JQ |
2010-11-04 | 2010/308 | 11:27:00 | 14.0 | 26.9 | 0.0 | - | 32.4 | 0.00 | 0.00 | 0.00 | -0.05 | 0.02 | 0.04 | Sensor leveled. Masses\'tuning.Change disk | Initial values of masses were not written down. | GM, JG |
2011-01-24 | 2011/024 | 16:48:00 | 12.4 | 12.8 | 0.0 | - | 18.3 | 0.87 | -0.52 | -0.99 | 0.00 | 0.00 | 0.00 | Dismantle | - | JP, JQ |